+86-21-5432 2103

PV Module Aging Test Location: 首页 > Product Solutions > PV Module Aging Test > Outdoor Power Generation Comparison System

Outdoor Power Generation Comparison System

Product description Specifications Download

         The MPPT DC electronic load is connected at ends of the module to precisely compare the DC power generated by the module.


           Modular design, with flexible configuration

           Avoid interference from power grid factors and have high accuracy

           Access solar modules to track the maximum power point (MPPT)

    Low start-up voltage allows accurate tracking of MPPT in the full power range

    Control the on and off states of the system by time or voltage

    Record parameters such as voltage, current, power, and power generation of the modules .

    It can count minute electricity, hour electricity, daily electricity generation, monthly electricity generation, and annual electricity generation for easy inquiry.

    According to the power generation situation, and automatic sorting, then more intuitively to see the power generation capacity of various modules .

    Record parameters such as atmospheric temperature, atmospheric humidity, irradiance, and irradiation, and query in minutes, days, months, weeks, and years.

    Data can be exported and equipped with communication protocols for remote monitoring.

Project

Parameters

Irradiance range

02000W/

Irradiance accuracy

±5%

temperature range

-50200

Temperature accuracy

±1

Temperature repeatability

±0.5

Wind speed range

070m/s

Starting wind speed

0.25m/s

Wind direction range

0360°

Wind direction resolution

15°

Acquisition card acquisition frequency

1 second/time to 1000 seconds/time

Electronic load power

0400W

Electronic load current

030A

Electronic load current accuracy

0.1%FS

Voltage range

120V

Voltage accuracy

0.25%FS

Starting voltage

1V

MPPT tracking accuracy

99.6%


  • File name Release date Ooperating